The principle of the meter is very simple:You hookup a fully charged battery and load resistor to the meter, enter the value of the resistor and the cutoff voltage and start a discharge cycle. The meter will switch on the load using a power mosfet and continiously measure the battery voltage. To precisily measure the voltage a reference diode is used. During the discharge you can select to display the current voltage and current or the time expired and capacity so-far. If the cutoff voltage is reached the load will be disconnected and the capacity will be shown on the LCD display.
|
|||||
![]() |
|||||